Rev. P-071510 P/N VDC12248-MNL
BatteryMINDer
®
Model 12248
Page 1
INSTRUCTION MANUAL
BatteryMINDer
®
Model 12248*
Charger / Maintainer /
Desulphator-Conditioner
Rev. P-071510 P/N VDC12248-MNL
VDC Electronics, Inc.
147 D Woodbury Rd.
Huntington, NY 11743
www.vdcelectronics.com
READ AND SAVE THESE INSTRUCTIONS
*NOT for use with
Aviation Type 12-V Batteries
4 A
9LL=JQ'#(=J
¸
Charger / Maintainer /
Full Time De-Sulfator - Conditioner
12-Volt @ 2/4/ 8 Amp
Model 12248
8 A
2 A
AGM
GEL
FLOODED
Select
Charge Rate
Select
Battery Type
PRESSPRESSPRESS
Battery Condition Indication
Power On & Battery Connected
Before Start Charge:
Green = OK - Accepted
Yellow = Weak / Sulfated / Deep Discharge*
After Charge:
Green = Good
Yellow = Sulfated / Weak*
MAINTENANCE
(FLOAT)
Stop
Restart
VDC Electronics, Inc.
800-379-5579 (ET)
www.batteryminders.com
U.S. Patented & Patent Pending
Hold for 5 sec. for full reset
Green = Power ON
ERROR:
Red = Polarity Reversed
/ Battery = less than 3-Volts
*
Red (Blinking) = Battery not fully charged -
charger in float-maintenance mode
*
Charge - Float
Green (solid) = Charging
Green (blinking) = Float (maintenance)
*See Instruction Manual
For Lead-Acid
Batteries ONLY
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Desulphator-Conditioner

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 1INSTRUCTION MANUALBatteryMINDer® Model 12248*Charger / Maintainer /

Page 2

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 10Testing with a Hot/Cold Calibrated Hydrometer TesterRead the teste

Page 3

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 11Failure to test a “rested” (see pg. 9) battery will cause false re

Page 4

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 121109876453211121) Battery clip cordset w/ qwik connect plug (pgs.1

Page 5

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 13Simplified Operating Instructions(Read and thoroughly understand A

Page 6

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 14Battery Condition IndicationBattery connected BEFORE full Charge:

Page 7

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 154 A9LL=JQ'#(=J¸Charger / Maintainer / Full Time De-Sulfator

Page 8

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 16Detailed Operation Instructions Model 12248After carefully reading

Page 9 - Specific Gravity – Capacity

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 17Correct polarity and a good connection will be your reward. Attach

Page 10 - BatteryMINDer

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 184. After selecting battery type, determine the cor-rect charge rat

Page 11

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 19Note: If the battery does not have a mini-mum no load O

Page 12 - Model 12248

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 2TABLE OF CONTENTSSafety Instructions...

Page 13 - ®

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 20If battery is not defective it should be able to be fully charged

Page 14

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 21INSTRUCTIONS:TEMPERATURE SENSOR Type: ABS-248 (At-the-Battery Sens

Page 15 - 9LL=JQ'#(=J

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 22Finally, if placing the sensor on the battery in not practical, pl

Page 16

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 23The chart below shows the need to regulate the output voltage of t

Page 17 - Positive ground installations

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 24Gel Charge and Float Voltages at Various Temperature Ranges**Temp°

Page 18

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 25MAINTAINING MULTIPLE BATTERIESBatteryMINDer 12248 maintenance char

Page 19

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 26VDC Electronics, Inc. does not make nor can it supply or recommend

Page 20

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 27Troubleshooting - Model 12248We use the word “Indicator” to mean t

Page 21

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 28and must stay connected to charger and remain in Maintenance-Float

Page 22

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 29DETAILED SPECIFICATIONS - VDC Model No. 1224814.1V / 14.4V / 14.6V

Page 23

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 3Underwriters Laboratories (UL)REQUIRED SAFETY INSTRUCTIONSWARNINGTO

Page 24

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 30DETAILED SPECIFICATIONS - VDC Model No. 12248 (con’t.)• Charging

Page 25

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 31DETAILED SPECIFICATIONS - VDC Model No. 12248 (con’t.)Absorption m

Page 26

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 32DETAILED SPECIFICATIONS - VDC Model No. 12248 (con’t.)Battery sulp

Page 27

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 33DETAILED SPECIFICATIONS - VDC Model No. 12248 (con’t.)TransformerT

Page 28

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 346OLTSTART6OLTSoft Start(0.5A/1A/2A)(6 Hours time-outlimited

Page 29

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 35FOR REPAIR OR REPLACEMENTIn the event that you believe your produc

Page 30

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 36Guarantee and WarrantyNOTE: ALL returns must be authorized by VDC

Page 31

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 4To reduce risk of battery explosion, follow these instructions and

Page 32

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 5NEVER CHARGE A FROZEN BATTERY OR ONE AT A TEMPERATURE ABOVE 123° F.

Page 33

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 6DC CONNECTION PRECAUTIONSa. Connect and disconnect DC output clips

Page 34 - #URRENT

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 7DO NOT CONNECT CLIP TO CARBURETOR, FUEL LINES, OR SHEET METAL BODY

Page 35

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 8QUALIFYING YOUR BATTERY:Preliminary RequirementsNOTE: The BatteryMI

Page 36

Rev. P-071510 P/N VDC12248-MNLBatteryMINDer® Model 12248Page 93. Refill each cell with distilled water only to the liquid level i